Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Braz. oral res. (Online) ; 29(1): 1-6, 2015. tab, ilus
Article in English | LILACS | ID: lil-777271

ABSTRACT

The aim of this study was to evaluate the amount of deformation from compression caused by different diameters of Morse taper implants and the residual deformation after load removal. Thirty Morse taper implants lacking external threads were divided into 3 groups (n = 10) according to their diameter as follows: 3.5 mm, 4.0 mm and 5.0 mm. Two-piece abutments were fixed into the implants, and the samples were subjected to compressive axial loading up to 1500 N of force. During the test, one strain gauge remained fixed to the cervical portion of each implant to measure the strain variation. The strain values were recorded at two different time points: at the maximum load (1500 N) and 60 seconds after load removal. To calculate the strain at the implant/abutment interface, a mathematical formula was applied. Data were analyzed using a one-way Anova and Tukey’s test (α = 0.05). The 5.0 mm diameter implant showed a significantly lower strain (650.5 μS ± 170.0) than the 4.0 mm group (1170.2 μS ± 374.7) and the 3.5 mm group (1388.1 μS ± 326.6) (p < 0.001), regardless of the load presence. The strain values decreased by approximately 50% after removal of the load, regardless of the implant diameter. The 5.0 mm implant showed a significantly lower strain at the implant/abutment interface (943.4 μS ± 504.5) than the 4.0 mm group (1057.4 μS ± 681.3) and the 3.5 mm group (1159.6 μS ± 425.9) (p < 0.001). According to the results of this study, the diameter influenced the strain around the internal and external walls of the cervical region of Morse taper implants; all diameters demonstrated clinically acceptable values of strain.


Subject(s)
Dental Implant-Abutment Design , Dental Implants , Analysis of Variance , Compressive Strength , Friction , Materials Testing , Mechanical Phenomena , Reference Values , Stress, Mechanical , Time Factors
2.
ImplantNews ; 11(5): 675-681, 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-731513

ABSTRACT

Este relato de caso demonstra o uso de um sistema de cirurgia guiada sem retalho para colocação de uma prótese em carga imediata. Uma paciente do gênero feminino, 38 anos de idade, compareceu à clínica com queixas estéticas e funcionais. Inicialmente, os dentes remanescentes na mandíbula foram extraídos e uma prótese implantossuportada foi instalada. Na maxila, após o enceramento diagnóstico, tomografias computadorizadas feixe cônico (TCFC) foram realizadas uma tomografia da paciente com o guia tomográfico em posição e um escaneamento apenas do guia. As imagens foram fundidas em um software específico, e o planejamento virtual foi realizado. Seis implantes de titânio com conexão cone-morse foram instalados (torque final 32 Ncm), conectados aos minipilares, e o processo de moldagem foi finalizado. A infraestrutura desenhada recebeu a prótese maxilar definitiva através de um processo de cimentação passiva (Panavia) dos cilindros de titânio, em carga imediata. Após três meses, foram realizados exames clínicos e uma nova radiografia panorâmica. A prótese foi removida e os implantes foram testados individualmente. Todos os implantes apresentaram-se osseointegrados, sem sinais e sintomas irreversíveis ou persistentes (dor, infecção, neuropatias, parestesia ou mobilidade) e sem evidência de radioluminescência peri-implantar. Dentro das limitações do caso e mediante indicação clínica adequada, a técnica de carga imediata com cirurgia sem retalho fornece excelentes resultados estéticos, reduzindo o tempo cirúrgico e os sintomas pós-operatórios, ao mesmo tempo em que preserva maior quantidade de tecido.


This case report demonstrates the use of flapless guided surgery for immediate implant placement and loading. A female, 38 years-old patient was referred with claims of poor esthetics and function. First, all remaining mandibular teeth were extracted and an implant-supported prosthesis delivered. For the maxillary arch, CBCTs were made based on the diagnostic wax-up, with and without the tomographic guide. Images were superimposed with the aid of an specifi c software, and the virtual planning was made. Six cone-morse dental titanium implants (32 Ncm torque) were installed and connected to mini-abutments for impression procedures. The designed framework received the definative prosthesis through passive cementation (Panavia) using titanium cylinders under immediate loading. Latter, the prosthesis was removed and all implants tested individually, showing osseointegration and no signs of irreversible or persistent symptoms (pain, infection, neuropathies, paresthesia, or mobility) or peri-implant radiolucency were seen. Within the limits of this case and following adequate clinical indication, the fl apless guided surgery with immediate implant loading provided excellent esthetic results, shortening the surgical time and postoperative discomfort, while also allowing for more tissue preservation


Subject(s)
Humans , Female , Adult , Dental Implants , Immediate Dental Implant Loading , Surgery, Computer-Assisted
3.
Ortho Sci., Orthod. sci. pract ; 3(13): 467-474, 2011. ilus
Article in Portuguese | LILACS, BBO | ID: lil-589664

ABSTRACT

Na busca de melhor entendimento biomecânico, diversos métodos têm sido utilizados na tentativa de predizer a resposta tecidual frente à aplicação de carga ortodôntica. Mesmo diante de algumas dificuldades oferecidas pela vasta complexidade dos tecidos orais, o método de análise por elementos finitos é o mais adequado para a simulação das propriedades desses componentes. Diante disso, o objetivo desse estudo foi discutir, a partir de releitura da literatura científica, parâmetros metodológicos da aplicação dessa metodologia em estudos ortodônticos. Após estabelecidos os parâmetros a serem discutidos (propriedades dos materiais, linearidade de análises e condições de contorno), a busca dos artigos foi feita pela base de dados online PubMed, relacionando as palavraschaves “orthodontics” e “finite element analysis”, e também por meio de busca manual de autores renomados nessa área. Foram selecionados artigos que apresentassem considerações críticas sobre os parâmetros metodológicos supracitados. Após discussão crítica dos aspectos propostos, pode-se concluir que diante do grande leque de opções metodológicas, as variáveis abordadas ao longo desse artigo devem ser cuidadosamente consideradas para avaliação do objetivo proposto pelo estudo, assim como para a correta interpretação dos resultados obtidos por meio da análise por elementos finitos.


In search of better biomechanical understanding, several methods have been used in an attempt to predict the tissue response to the application of orthodontic load. Even with some difficulties of the vast complexity of the oral tissues, the method of finite element analysis is most suitable for simulating the properties of these components. Therefore, the objective of this study was to discuss, through scientific literature reading, methodological parameters of the application of this technique in orthodontic studies. After set the parameters to be discussed (material properties, linear analysis and boundary conditions), the articles search was made by PubMed online database, with “orthodontics” and “finite element analysis” key words, and also through a manual search of authors in this area. Articles were selected about the mention of methodological parameters above. After critical discussion, it can be concluded that given the large number of methodological options, the variables discussed throughout this article should be carefully considered to assess the goal proposed by study, as well as the correct interpretation of the results obtained by finite elements analysis.


Subject(s)
Biomechanical Phenomena , Orthodontics , Finite Element Analysis
4.
Ortho Sci., Orthod. sci. pract ; 4(15): 669-676, 2011. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-605617

ABSTRACT

O objetivo do tratamento ortopédico precoce é corrigir o desenvolvimento esquelético, dentoalveolar e alterações funcionais. Com isso, pode-se ajudar a minimizar a possibilidade de um tratamento ortodôntico mais complexo envolvendo extração de dentes permanentes ou cirurgia ortognática. No caso clínico apresentado utilizou-se o protocolo de ativação de disjunção palatal que preconiza a ativação e desativação do disjuntor por semanas subsequentes. Em exame intraoral do paciente foi observada mordida cruzada anterior, má-oclusão Classe I de Angle, ausência do elemento 12 e elemento 22 conóide. Ao final de 10 meses de tratamento, após 6 meses de correção do trespasse horizontal, observou-se um aumento de 3° no SNA e 7° no NAP que após o tratamento significaram, respectivamente, um posicionamento maxilar em relação à base do crânio dentro dos padrões de normalidade (SNA=80°+ 2) e o perfil com característica convexa (NAP=7°). Diante dos dados clínicos e cefalométricos obtidos após o tratamento com protração maxilar associada à disjunção palatina com protocolo de ativação/desativação alternado pode-se concluir que obteve-se sucesso na correção do trespasse horizontal do caso clínico apresentado.


The aim of early orthopedic treatment is to correct the skeletal and dentoalveolar development and functional changes. Therewith, might be possible minimize the complexity of an orthodontic treatment, avoiding ex-traction of permanent teeth or orthognathic surgery. The case reported the protocol used for palatal disjunction which activation and deactivation calls for following weeks. During intraoral examination was observed anterior crossbite, Class I Angle malocclusion, absence of element 12 and element 22 conoid. At 10 months of treatment, 6 months after overjet correction, was observed an increase of 3° in SNA and 7° in NAP. This results means, respectively, a normal maxilla position in relation to the skull base (SNA = 80 ° + 2) and convex profile (NAP = 7°). Considering the clinical and cephalometric data obtained after treatment with maxillary protraction associated with rapid palatal expansion - protocol of activation/deactivation switched - could be conclude that the overjet of this clinical case was corrected successfully.


Subject(s)
Humans , Male , Child , Malocclusion, Angle Class I , Palatal Expansion Technique
5.
Barbarói ; (33): 178-193, ago.-dez. 2010. ilus
Article in Portuguese | LILACS | ID: lil-588263

ABSTRACT

Objetivo: avaliar a prevalência de transtornos mentais comuns entre a população de rua. Métodos: Estudo transversal com 245 moradores de rua em Belo Horizonte. Os transtornos mentais comuns e as categorias de sintomas foram avaliados pelo Self Reporting Questionnaire (SRQ-20). Resultados: 49,48 da população tem problemas mentais. Na distribuição dos sintomas há prevalência de depressão e ansiedade, seguida por sintomas somáticos, decréscimo de energia vital e pensamentos depressivos. Conclusão: A prevalência de transtornos mentais comuns encontradas em homens adultos que vivem nas ruas de Belo Horizonte pode ser o resultado da vulnerabilidade deste grupo social.


Objective: To assess the prevalence of common mental disorders among the homeless population. Methods: Cross sectional study with 245 homeless men in Belo Horizonte. Common mental disorders and the categories of symptoms were evaluated by the Self-Reporting Questionnaire (SRQ-20). Results: 49.48 of the population has mental disorders. In the distribution of symptoms there is prevalence of depressed mood and anxiety, followed by somatic symptoms, decrease of vital energy and depressive thoughts. Conclusion: The prevalence of common mental disorders found in adult males living on the streets of Belo Horizonte can be the result of the vulnerability of this social group.


Subject(s)
Mental Disorders , Mental Health , Social Vulnerability
6.
SMAD, Rev. eletrônica saúde mental alcool drog ; 6(spe): 536-555, out. 2010. tab
Article in Portuguese | LILACS | ID: lil-603802

ABSTRACT

Este estudo epidemiológico, de tipo descritivo, buscou conhecer a prevalência de consumo de álcool entre a população em situação de rua. Para coleta de dados, utilizou-se o AUDIT com 245 homens em situação de rua, de Belo Horizonte. Verificou-se maior frequência do uso nocivo e provável dependência nos adultos maduros e maior frequência do padrão de risco para aqueles que vivem em situação de rua, em período superior a 6 anos, e entre os que dormem em vias públicas. Este estudo realça a importância da construção de políticas de saúde voltadas para a população em situação de rua.


This descriptive, epidemiologic study aimed at identifying the prevalence of alcohol use among the homeless population. Data collection was performed using AUDIT with 245 men living on the streets of Belo Horizonte. It was found there is a high frequency of harmful alcohol use pattern with probable dependence in mature adults and a high rate of risk pattern for those living on the streets for over 6 years and among those sleeping in public areas. This study highlights the importance of building health policies that are aimed at the homeless population.


Este estudio epidemiológico de carácter descriptivo, buscó conocer la prevalencia de consumo de alcohol entre la población en situación de calle. Para la recolección de datos se utilizó el AUDIT con 245 hombres en situación de calle en Belo Horizonte. Se verifica mayor frecuencia del uso nocivo y probable dependencia en adultos maduros y mayor frecuencia del estándar de riesgo para los que viven en situación de calle por período superior a 6 años y entre los que duermen en la vía pública. Este estudio realza la importancia de construcción de políticas de salud orientadas a la población en situación de calle.


Subject(s)
Humans , Male , Adult , Alcoholism , Ill-Housed Persons
7.
Braz. j. oral sci ; 9(2): 128-132, Apr.-June 2010. ilus, tab
Article in English | LILACS, BBO | ID: lil-578077

ABSTRACT

Aim: To evaluate the root topography of human teeth affected by periodontitis, after different root surface treatments. Methods: Forty-two periodontally affected single-rooted human teeth were selected and randomly divided into 7 groups (n=6): Cont- control group, which received no treatment; Sca- root surface scaling and root planning with curettes; ScaPh- Sca followed by 37%phosphoric acid gel etching for 15 s; ScaEdta- Sca followed by 24% EDTA gel pH 7 for 1 min; ScaCi- Sca followed by 30% citric acid pH 1.6 for 5 min; ScaTe- Sca followed by - mixture obtained by 500 mg tetracycline capsule dissolved in saline solution for 3 min; ScaTeg- Sca followed by 0.2 g/mL tetracycline gel pH 1.8 for 1 min. The specimens were analyzed by scanning electronic microscopy to verify the presence of calculus, demineralization level and residues of the product. Results: Calculus deposits were found in all control specimens. ScaEdta, ScaCi and ScaTeg removed completely calculus deposits and resulted in adequate demineralization without smear layer and smear plug on root surface. ScaTe produced great tetracycline residues with several demineralization areas on root dentin surface. Conclusions: ScaEdta, ScaCi and ScaTeg produced clean root surfaces associated with regular dentin demineralization.


Subject(s)
Humans , Dental Scaling , Tooth Demineralization/chemically induced , Periodontitis/drug therapy , Tooth Root , Smear Layer , Citric Acid/therapeutic use , Surface Properties , Tetracycline/therapeutic use
8.
Braz. dent. j ; 21(2): 130-136, 2010. tab, ilus
Article in English | LILACS | ID: lil-551933

ABSTRACT

The aim of this study was to evaluate the influence of different periodontal therapies on the integrity of indirect restorations by scanning electron microscopy (SEM). Sixty single-rooted bovine teeth were selected and randomly assigned to 12 groups. Inlay cavities were prepared in the cervical region on the center of the cementoenamel junction, and were restored with laboratory processed resin and luted with a resin cement. Twelve periodontal therapies were used (n= 5): C: control (no treatment); MS: manual scaling with Gracey curettes; US: ultrasonic scaling; PP: prophylaxis with prophylactic paste; PS: prophylaxis with pumice-stone; SBJ: sodium bicarbonate jet; MS/PP; MS/PS; MS/SBJ; US/PP; US/PS; US/SBJ. The specimens were prepared and analyzed by SEM. SEM micrographs at ×100 to ×1000 magnification were obtained from the surface of the laboratory resin and the interface of the indirect restorations. The images were evaluated by 3 skillful, calibrated, blinded observers as to the presence of grooves, microcavities and fracture of margins. The results showed that PS produced groves on restoration surface. MS and US produced groves and marginal fractures on the restorations. SBJ resulted in resin cement degradation. These results suggest that except for PS, all procedures had deleterious effects on the marginal integrity of indirect restorations.


O objetivo desse estudo foi avaliar a influência de diferentes terapias periodontais na integridade de restaurações indiretas por meio de microscopia eletrônica de varredura (MEV). Sessenta raízes bovinas foram selecionadas e aleatoriamente divididas em 12 grupos. Preparos cavitários inlay foram realizados na região cervical central da junção cemento-esmalte e restaurados com resina laboratorial cimentado com cimento resinoso. Doze terapias periodontais foram usadas (n=5): C-sem tratamento (controle); MS-raspagem manual com cureta Gracey; US-raspagem com ultra-som; PP- profilaxia com pasta profilática; PS-profilaxia com pedra pomes; SBJ-jato de bicarbonato; MS/PP; MS/PS; MS/SBJ; US/PP; US/PS; US/SBJ. As amostras foram preparados e submetidas a MEV. Imagens, de ×100 a ×1000, da superfície da resina laboratorial e da interface das restaurações indiretas foram obtidas. As imagens foram avaliadas em procedimento cego por 3 observadores habilitados previamente calibrados seguindo os seguintes critérios: ranhuras, microcavidades e fratura de margem. Os resultados mostraram que a profilaxia com pedra pomes promoveu ranhuras na superfície das restaurações. Raspagem manual e ultrasônica promoveram ranhuras e fratura de margem das restaurações. Jato de bicarbonato resultou em degradação de cimento resinoso. Os resultados sugeriram que, exceto a profilaxia com pasta profilática, todos os procedimentos resultaram em efeitos deletérios na integridade da margem das restaurações indiretas.


Subject(s)
Animals , Cattle , Dental Marginal Adaptation , Dental Scaling , Inlays , Resin Cements/chemistry , Tooth Cervix/ultrastructure , Dental Restoration Failure , Dental Restoration, Permanent/methods , Observer Variation , Random Allocation , Single-Blind Method , Stress, Mechanical , Surface Properties , Tooth Cervix/drug effects
9.
J. bras. psiquiatr ; 59(1): 10-16, 2010. tab
Article in Portuguese | LILACS | ID: lil-547624

ABSTRACT

Objetivo: Este estudo objetiva avaliar a prevalência de depressão entre a população de rua. Métodos: Realizado estudo transversal com homens adultos em situação de rua de Belo Horizonte. Para coleta de dados, foi utilizado o Inventário de Depressão de Beck e análise foi realizada por meio da estatística descritiva. Resultados: Evidenciam-se alta prevalência de depressão e o grau de severidade dos sintomas depressivos relacionados à faixa etária, tempo de moradia na rua, local onde dorme, relato de problema de saúde e uso de medicamento da população masculina adulta em situação de rua. Conclusão: O presente estudo ressalta a importância de construção de políticas de saúde voltadas para a população de rua.


Objective: This study aims to evaluate the prevalence of depression among the homeless population. Methods: A cross-sectional study was conducted with adult men in the streets of Belo Horizonte. To collect data we used the Beck Depression Inventory and analysis was performed using descriptive statistics. Results: Shows a high prevalence of depression and severity of depressive symptoms related to age, full-time dwelling on the street, where he sleeps, reported health problems and medication use in the adult male population in the streets. Conclusion: This study emphasizes the importance of building health policies for the homeless.


Subject(s)
Humans , Male , Adult , Depression/diagnosis , Depression/epidemiology , Ill-Housed Persons , Men/psychology , Mental Disorders , Poverty , Brazil , Cross-Sectional Studies , Educational Status , Prevalence , Surveys and Questionnaires
10.
J. appl. oral sci ; 15(2): 94-98, Mar.-Apr. 2007. ilus, tab
Article in English | LILACS | ID: lil-452763

ABSTRACT

The aim of this study was to evaluate the influence of a low-viscosity bonding resin applied over a self-etching adhesive system on the microtensile bond strength (µTBS) of indirect restorations. Comparisons were made using One Up Bond F (OB) self-etching adhesive system, Single Bond (SB) one-bottle adhesive system and Scotchbond Multi Purpose Plus (SMP) bonding component. Thirty bovine incisors were extracted and decoronated at the cementoenamel junction. The labial surfaces were ground so that superficial dentin and deep dentin were exposed. The specimens were randomized to three groups (n=10): G1- OB; G2- OB + SMP; G3- SB. In G2, a layer of the SMP bonding was applied over the OB adhesive system. Indirect composite restorations were bonded using dual-cure cement under 500 g load for 5 min. The specimens were serially sectioned with a bonding area of ± 1.0 mm² in 3 regions: enamel (E), superficial dentin (SD) and deep dentin (DD). The sticks were fixed with cyanoacrylate adhesive and submitted to µTBS test at a crosshead speed of 0.5 mm/min in a mechanical testing machine (EMIC DL 2000). The fractured specimens were examined under scanning electron microscopy to determine the failure mode. Data were analyzed by one-way ANOVA followed by Tukey's test (p<0.05). µTBS means (in MPa) were: G1/E: 15.5 ± 3.5b; G1/SD: 22.7 ± 7.6a; G1/DD: 19.4 ± 9.4a; G2/E: 15.9 ± 5.8b; G2/SD: 19.9 ± 6.9a; G2/DD: 15.3 ± 4.9a; G3/E: 23.2 ± 7.3a; G3/SD: 20.4 ± 8.2a; G3/DD: 19.1 ± 8.7a. The results showed that the use of a low viscosity bonding resin did not affect the µTBS means when associated with a self-etching adhesive system. The self-etching adhesive system was significantly more efficient in dentin than in enamel, while the one-bottle system was significantly more efficient in enamel when compared to the self-etching adhesive system.

11.
Rev. odontol. UNESP ; 35(3): 149-156, jul.-set. 2006. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-512575

ABSTRACT

Avaliar, por meio de questionário e análise morfológica em microscopia eletrônica de varredura, a qualidade de instrumentos rotatórios usados por acadêmicos de odontologia. Material e Método: 24 alunos do 5º ao 8º períodos foram aleatoriamente selecionados e abordados quanto: freqüência de uso, período de troca, meio de armazenagem, forma de limpeza, métodos de desinfecção e esterilização, disposição de auto-uso. Para a análise morfológica foram recolhidas pontas diamantadas #1014 (P) e brocas carbide esféricas #2 (B) (n = 48) com tempo médio de uso de 6 meses a 1 ano, as quais foram analisadas por meio de microscopia eletrônica de varredura observando: corrosão, integridade das lâminas de corte, retenção de resíduos, perda de diamante. Os dados foram analisados de forma descritiva. Resultados: o questionário mostrou: 67% usavam P e B semanalmente; 62% nunca as trocaram; 67% armazenavam em broqueiro de metal; 54% utilizavam água, sabão e escova para limpeza e 17% não limpavam; 50% utilizavam imersão em álcool para desinfecção; 58% não esterilizavam os instrumentos rotatórios; 29% relatavam não concordar com o uso em si mesmo de P e B. A análise morfológica em MEV mostrou que, em B: 42% apresentavam corrosão leve; 79% perda parcial da integridade das lâminas; 60% apresentavam pequena quantidade de resíduo; 79% eram inadequadas para uso, e, em P: 67% possuiam corrosão leve; 90% presença de resíduo; 48% perda de diamante; 83% eram inadequadas para o uso. Conclusão: concluiu-se que não há relação dos atos de armazenagem, limpeza e esterilização de instrumentos com qualidade morfológica dos instrumentos rotatórios. As brocas e as pontas diamantadas empregadas não apresentavam qualidade adequada para o uso clínico.


To evaluate the rotatory instruments quality of academics by questionnaire and morphologic analysis by electronic scanning microscopy. Materials and Methods: twenty four students in different dental school program periods were asked about use frequency, exchange, period of exchange, storage form, cleaning form, disinfection and sterilization methods, capacity of rotatory instruments self use. For morphologic analysis had been collected diamond burs #1014 (P) and carbide burs #2 (B) (n = 48), with average use time among 6 months and 1 year, which had been analyzed by electronic scanning microscopy observing: corrosion, blade integrity, residues retention, and diamond loss. The data had been tabulated and analyzed of descriptive form. Results: the questionnaire showed: 67% use P and B weekly, 62% never had changed them; 67% store in metallic bur stand, 54% use water, soap and brush for cleaner and 17% do not clean, 50% use alcohol immersion for disinfection, 58% do not sterilized the rotatory instruments , 29% do not agree use P and B in itself. The SEM analyses showed that in B: 42% few corrosion; 79% partial loss of blade integrity; 60% small amount of residue; 79% inadequate for use and, in P: 67% few corrosion; 90 % presence of residue; 48% diamond loss; 83% inadequate for use. Conclusion: it can be conclude that there is not relation of storage form, cleaning form and instruments sterilization with the morphologic rotatory instruments quality. Burs and diamond burs used by academics do not present quality for clinical use.


Subject(s)
Dental Instruments , Microscopy, Electron, Scanning , Dental Waste
12.
Ciênc. odontol. bras ; 9(2): 67-74, abr.-jun. 2006. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-457307

ABSTRACT

Este trabalho avaliou a resistência adesiva (µTBS) na fixação de restaurações indiretas por meio de cimento resinoso e adesivo auto-condicionante sob influência de diferentes tratamentos prévios de esmalte e dentina. Trinta incisivos bovinos foram extraídos e tiveram suas raízes cortadas na junção cemento-esmalte. A superfície vestibular dos dentes foi lixada até exposição de dentina superficial, padronizando a formação de smear layer. As amostras foram divididas aleatoriamente em três grupos (n=10): G1: aplicação do adesivo auto-condicionante One up Bond F (OB), seguindo as instruções do fabricante; G2:condicionamento com ácido fosfórico à 37% em esmalte e dentina seguindo aplicação de (OB); G3: jateamento com óxido de alumínio 50µm em esmalte e dentina previamente à aplicação de (OB). Restaurações indiretas com resina composta foram fixadas usando cimento resinoso dual e as amostras foram cortadas com área adesiva de aproximadamente 1,0 mm² em três regiões: esmalte (E), dentina periférica (DP) e dentina central (DC). Foram submetidas a ensaio de microtração em máquina de ensaio mecânico em velocidade de 0,5mm/min. Após fratura, as amostras foram analisadas em Microscopia Eletrônica de Varredura (MEV) para avaliação do padrão de fratura. Os valores de (µTBS) foram expressos em MPa e os dados foram analisados em ANOVA seguido por teste Tukey (p<0,05). Os resultados foram: E/G2: 30,4±11,9a; E/G3: 16,0±8,9b; E/G1: 15,8±5,8b; DP/G1: 24,2±12,1a; DP/G3: 15,2±7,1b; DP/G2: 15,0±9,8b; DC/G1: 17,3±10,4a; DC/G3: 11,6±3,5b; DC/G2: 11,4±5,2b. O jateamento não aumentos os valores de (µTBS). O prévio condicionamento ácido aumentou a resistência adesiva em esmalte e diminuiu em dentina.


Subject(s)
Animals , Cattle , Air Abrasion, Dental , Dental Restoration, Permanent , Dentin-Bonding Agents , Phosphoric Acids , Tensile Strength , Tooth Preparation , Analysis of Variance , Microscopy, Electron, Scanning , Smear Layer
SELECTION OF CITATIONS
SEARCH DETAIL